Microclip XL- Personal Multigas Detector, No Internal Pump – Model No. MCXL-XWHM-Y-NA

Please login or register to see price

Microclip XL- Personal Multigas Detector, No Internal Pump – Model No. MCXL-XWHM-Y-NA

This product can only be purchased by members.
SKU: MCXL-XWHM-Y-NA Categories: ,

BW GasAlert MicroClip XL Series Multi-Gas Detector Offers

The GasAlertMicroClip XL is designed to simplify multi-gas monitoring with a combination of ease of use, durability, compliance insurance, performance and affordability. This multi-gas detector provides continuous visual confirmation of detector operation and compliance with the IntelliFlash feature and the simple one-button operation offers ultimate ease of use and significantly reduces time spent training. The GasAlert MicroClip XL is fully compatible with the BW MicroDock II automatic test and calibration system.

The MicroClip XL has been designed for enhanced battery operation and improved functionality in cold weather environments. For simple, cost-effective management of your records, calibration and bump testing, choose BW’s MicroDock II automatic test and calibration system and Fleet Manager II software.


Supported Gases

  • H2S
  • CO
  • O2
  • LEL

Features

  • Designed for cold weather performance
  • IntelliFlash verifies operation and compliance to both the user and supervisor
  • Tamper-proof, one button operation
  • Powered by a rechargeable lithium polymer battery
  • Continuous LCD shows real-time gas concentrations
  • Compact and lightweight design makes it comfortable to wear
  • Water-resistant
  • Simple automatic calibration procedure; compatible with BW MicroDock II automatic test and calibration station
  • Full function self-test of sensor, battery status, circuit integrity and audible/visual alarms on start up
  • Bright wide-angled visual alarm bars
  • Built-in concussion-proof boot
  • Multi-language support in English, French, German, Spanish and Portuguese
  • Conveniently manage your fleet using Fleet Manager II

Confined Space Kit Available

The MicroClip XL can also be used in a confined space kit. A confined space can represent a risk for the health and safety of anyone who enters, because it has restricted entrance and exit and the possibility of dangerous substances in the atmosphere. The air within the confined space should be tested from outside before entry. A trained worker should use remote probes and sampling lines with properly calibrated and maintained equipment to verify that oxygen content is within safe limits and that a hazardous atmosphere is not present.

 

Key Features:

 

  • Smallest, lightest four gas monitor
  • Built-in datalogging & event logging
  • IP66/67 rating for moisture/dirt protection
  • Rechargeable battery pack for longer battery life
  • Compatible with SamplerPak pump for remote sampling
  • IntelliFlash verifies operation and compliance to both the user and supervisor
  • Tamper-proof, one button operation
  • Compatible with the Sampler motorized remote sampling pump
  • Equipped with internal vibrating alarm for high noise areas
  • Powered by a lithium polymer battery
  • Multi-language support in English, French, German, Spanish and Portuguese
  • Conveniently manage your fleet using Fleet Manager II

Specifications:

Sensor Specifications

Gas Measuring Range Resolution
H2S 0-100 ppm 1 ppm
CO 0-500 ppm 1 ppm
O2 0-30.0% 0.1%
Combustible gases 0-100% LEL
0-5.0% v/v
1%
0.1%
Alarm setpoints for all sensors are user adjustable. Setpoints are automatically displayed during instrument start up.

Other Specifications

Size 4.4 x 2.4 x 1.2 in. / 11.3 x 6.0 x 3.1 cm
Weight 6.7 oz. / 190 g
Temperature -4 to +122°F / -20 to +50°C
Humidity 0% – 95% RH (non-condensing)
Alarms – Visual, vibrating, audible (95 dB)
– Low, high, STEL, TWA, OL (over limit)
Tests Audible/visual alarms on activation, sensors, battery and circuitry (continuous)
Typical battery life 18 hours; recharges in less than 6 hours
User options Confidence beep
Set STEL interval
Sensor on/off
Latching alarms
Safe display mode
Stealth mode
Calibration lock
Auto zero on start up
O2 auto calibration on start up
Set bump test interval
Force bump test when overdue
Ratings EMI/RFI: Complies with EMC Directive 2004/108/EC IP 66
Certifications and approvals Class I, Div. 1, Gr. A, B, C, D
ATEX: II 1 G
Ex ia IIC T4 Ga
IECEx: Ex ia IIC T4 Ga
European Conformity
Warranty Full two-year warranty including all sensors

Software:

Data storage and analysis has never been so simple. With the same look and feel as Fleet Manager, Fleet Manager II allows users to download information directly from BW instruments or the MicroDock II.

With improved functionality, users can:

  • Automatically create accurate and user-friendly reports
  • Easily sort, format and graph data as well as view history
  • Archive and share data easily, including databases
  • Download and manage calibration and bump check records as well as datalogged information onto any PC

Additional information

Weight 1.00 lbs
Dimensions 8 x 5.5 x 3 in

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.